Categories List
Recent Posts








In the explosive hazardous areas of petrochemical plants, oil and gas stations, hazardous-material storage facilities, and offshore platforms, ventilation equipment is not merely a process accessory—it is a foundational line of defense for the working environment. Conventional fans often struggle to reconcile material durability with explosion-proof reliability when faced with high salt spray, corrosive gases, and explosive atmospheres. The CNWINNEX BT35-11-3.15 Explosion-Proof Stainless Steel Axial Fan is engineered precisely for the ventilation demands of Zone 1 and Zone 2 high-risk environments. The product addresses corrosion challenges through stainless steel construction, establishes its explosion-proof baseline on ATEX and EN 60079 series standards, and balances 3,076 m³/h airflow with low-noise operation within a compact frame.
Core Advantages: Engineered for Hazardous-Area Ventilation
ATEX Compliance and Multi-Layer Explosion Protection. The fan is designed and manufactured in strict accordance with ATEX Directive 2014/34/EU, carrying the marking Ex db ib mb IIC T4 Gb. This marking indicates the integration of flameproof (db), intrinsically safe (ib), and encapsulated (mb) protection concepts, qualifying the unit for Zone 1 and Zone 2 explosive gas atmospheres, covering Group IIC gases and temperature class T4. For applications involving highly hazardous media such as hydrogen or acetylene, this rating provides a higher level of safety redundancy.
Stainless Steel Construction and Corrosion Resistance. The fan body and impeller of the BT35-11-3.15 are constructed from stainless steel (304 / 316L options available), effectively resisting corrosive gases and moisture in chemical process areas, offshore platforms, and high-salt-spray coastal environments. Compared with standard carbon steel or aluminum alloy impellers, the stainless steel solution better preserves the aerodynamic profile and structural integrity of the blades over extended operating cycles, reducing dynamic imbalance and airflow degradation caused by corrosion.
Balanced Low Noise and High Airflow. The fan employs an axial airflow design with 6–8 blades, delivering 3,076 m³/h at 2,900 RPM. Through aerodynamically optimized blade angles and a streamlined casing, the unit maintains high airflow output while keeping operating noise at a low level—suitable for control room surroundings, analyzer shelters, and occupied work areas with acoustic requirements.
Wide Voltage Adaptability and Custom Fabrication. Standard configuration includes a 380V three-phase power supply, compatible with 50Hz/60Hz frequencies. The fan supports custom fabrication, allowing adjustment of blade pitch, flange dimensions, and surface treatment to suit project-specific requirements. The operating temperature range covers standard industrial environments not exceeding 40°C, meeting the ventilation needs of most onshore and near-shore hazardous areas.
Technical Specifications Overview
Parameter Specification
Model BT35-11-3.15
Brand CNWINNEX
Voltage 380V (customizable)
Airflow Volume 3,076 m³/h
Power 0.37 kW
Speed 2,900 RPM
Airflow Direction Axial
Number of Blades 6–8
Material Stainless Steel (304 / 316L optional)
Operating Temperature Not exceeding 40°C
Explosion-Proof Marking Ex db ib mb IIC T4 Gb
Applicable Zones Zone 1 / Zone 2
Performance Features Explosion-proof, high airflow, low noise
Application Ventilation and air exchange
Typical Applications
l Petrochemical and Refinery Process Areas. Forced ventilation for plant buildings, pump houses, analyzer shelters, and hazardous-material warehouses. The stainless steel construction withstands acidic gases and humid conditions, while the explosion-proof rating covers Group IIC gas risks.
l Oil & Gas Stations and Offshore Platforms. Ventilation and exhaust for non-habitable hazardous compartments at desert oil and gas stations, near-shore platforms, and FPSOs (fixed installation scenarios), maintaining structural integrity and operational reliability under salt spray exposure.
l Hazardous-Material Storage and Battery Workshops. Daily air exchange and emergency exhaust for lithium battery production and storage areas and chemical warehouses. The Ex db ib mb IIC T4 Gb marking provides explosion protection for short-term release conditions that may occur within Zone 1.
l Power and Special Industries. Ventilation and heat dissipation for explosion-proof electrical equipment rooms, battery rooms, and military explosion-proof laboratories. The low-noise characteristics suit indoor work spaces with acoustic requirements.
Request Explosion-Proof Ventilation Selection Support
Please provide your hazardous area classification (Zone 1/2), gas group and temperature class, required airflow and total pressure, installation interface dimensions, and environmental corrosion conditions. The CNWINNEX engineering team will return an ATEX-compliant BT35-11-based explosion-proof stainless steel axial fan configuration.
Contact Us
Web: www.cnwinnex.com Email: info@cnwinnex.com WhatsApp: +86 193 5436 4613