Explosion-proof CCTV Surveillance Systems
CZ610-A Explosion Proof Integrated Camera
CZ610-A Explosion Proof Integrated Camera
Features

● ATEX, IECEx Approved
● Applicable for Gas Zone 1, Zone 2 (Class II A, IIB, IIC, T1–T6 group), Dust Zone 21, 22
● Certified to IEC/EN60079 (2014)
● Stainless steel 304 or 316L enclosure
● Surface optional electro-polished or painting
● Weather Proof IP68 (1.2m/45min)
● Wide voltage input: AC100-240V or AC24V
● Infrared lights, intelligent day/night vision
● Strong tempered glass, fit for hydrofluoric acid area
● Intelligent window defroster design
● Auto temperature adjust kit for aggressive area
● High precision wiper, support user-defined
● Symmetrical balancing design
● Intelligent long focal speed limit, fit for long distance monitoring
MESSAGE
PRODUCT DESCRIPTION

Features

● ATEX, IECEx Approved

● Applicable for Gas Zone 1, Zone 2 (Class II A, IIB, IIC, T1–T6 group), Dust Zone 21, 22

● Certified to IEC/EN60079 (2014)

● Stainless steel 304 or 316L enclosure

● Surface optional electro-polished or painting

● Weather Proof IP68 (1.2m/45min)

● Wide voltage input: AC100-240V or AC24V

● Infrared lights, intelligent day/night vision

● Strong tempered glass, fit for hydrofluoric acid area

● Intelligent window defroster design

● Auto temperature adjust kit for aggressive area

● High precision wiper, support user-defined

● Symmetrical balancing design

● Intelligent long focal speed limit, fit for long distance monitoring


Application

The CZ610-A is a CNWINNEX-designed classic explosion-proof integrated camera, integrating explosion-proof housing, pan/tilt, decoder, and wiper for easy installation and debugging. Suitable for Zone 1 and Zone 2 hazardous areas with explosive gases (IIA, IIB, IIC, T1–T6) and Zone 21 and Zone 22 dust hazardous areas. Ideal for refining, chemical, oil extraction, gas production, fireworks, grain storage, petrol stations, etc.


Ex-Proof Marking

● Marking: II 2G Ex db op is IIC T6 Gb, II 2D Ex tb op is IIC T80 °C Db

● Standards: IEC/EN60079

● Certificate: Presafe 17 ATEX 11328X, IECEx PRE 18.0030X


Environment

● Ambient Temperature: -40°C ~ +60°C

● Atmospheric Pressure: 80kPa ~ 120kPa

● Relative Humidity: ≤95% RH (+25°C)


Mechanical

● Material: Stainless steel 304/316L

● Ingress Protection: IP68 (1.2m/45min)

● Cable Glands: M25x1.5 or M27x1.25

● Cable Entry: 1 pc

● Pan: 360° continuous, max 40°/s

● Tilt: -90° ~ 90°, max 30°/s

● Wiper: 30 ± 10 times/min

● Weight: 40kg

● Mount: Wall, pole (or custom)


Electrical

● Voltage: 100~240VAC or 24VAC

● Current: Max 3.0A

● Power: ≤75W

● IR View Distance: 200m

● Protocol: Pelco-D, Pelco-P

● Rate: 2400~19200bps

● Output: AV/RJ45

● Long Focal Limit Speed: Yes

● Preset: 128/255

● Preset Precision: ≤0.1°

● Surge Protect: Optional, TVS 6000V

● Fiber: Optional

● Audio: Optional

● Alarm: Optional


Camera Specifications

● Image Sensor: 1/2.8 inch STARVIS™ CMOS

● Effective Pixels: 2 MP, 1920×1080

● Min. Illumination: Color 0.05Lux/F1.6, B/W 0.005Lux/F1.6

● Noise Reduction: Ultra DNR (2D/3D)

● White Balance: Auto, ATW, Indoor, Outdoor, Manual

● Gain Control: Auto/Manual

● S/N Ratio: ≥55dB

● Electronic Shutter: 1/1 ~ 1/30000s

● EIS: Support

● Optical Defog: Support

● Backlight Compensation: Support

● Digital Zoom: 16X

● Day/Night: Auto(ICR) / Color / B/W

● Focus Control: Auto/Manual

● Focal Length: 4.5mm ~ 135mm

● Angle of View: H: 67.8° ~ 2.77°

● Close Focus Distance: 100mm ~ 1000mm

● Optical Zoom: 30X

● Max Aperture: F1.6 ~ F4.4


Video Compression & Protocol

● Compression: H.265, H.264, M-JPEG

● Protocol: IPv4/IPv6, HTTP, HTTPS, 802.1x, Qos, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE


Dimensions

● Size: 511mm × 295mm × 420mm

● Net Weight: 40kg


FAQ
A:

CNWINNEX explosion-proof systems are widely deployed in oil & gas, petrochemicals, pharmaceuticals, ports & terminals, mining, power generation, offshore platforms, and other areas where flammable gases or dusts are present. Typical applications include control room climate control, hazardous area logistics and access management, video surveillance & security, pressurized analyzer shelters, robotic inspection, as well as custom explosion-proof enclosures and system integration.

A:

An explosion-proof air conditioner is a specialized HVAC unit designed for hazardous environments where flammable gases, vapors, or combustible dusts are present (e.g., petrochemical plants, gas stations, paint booths, pharmaceutical labs).

The most critical difference from a standard air conditioner lies in “active ignition prevention.” Standard units generate tiny sparks during normal operation – such as when relays open/close, compressors start/stop, or circuits make/break. While safe in normal air, these sparks can be deadly in an explosive atmosphere.

A:

CNWINNEX’s explosion-proof design is based on the T4 temperature class. For high-temperature regions such as the Middle East or areas with extreme summer heat, we offer custom units rated for ambient temperatures up to 60°C (140°F) , ensuring reliable operation without overload in harsh tropical climates. For cold regions, we offer custom units rated for ambient temperatures as low as -50°C (-58°F) , guaranteeing safe operation in extreme arctic conditions.

A:

The explosion-proof rating of CNWINNEX air conditioners is:
Ex 2 G D Ex db ib mb IIB T4 Gb / Ex 2 G D Ex db ib mb IIC T4 Gb / Ex ib mb tb IIIC T130°C Db
●For Gas (G): Ex db ib mb IIC T4 Gb
Suitable for IIC gas groups (including hydrogen, acetylene, etc.), using flameproof (db), intrinsic safety (ib), and encapsulated (mb) combined protection. Temperature class T4 (max surface temperature ≤135°C), Equipment Protection Level Gb.
●For Dust (D): Ex ib mb tb IIIC T130°C Db
Suitable for IIIC conductive dusts, using intrinsic safety (ib), encapsulation (mb), and dust-tight (tb) protection. Maximum surface temperature 130°C, Equipment Protection Level Db.

A:

CNWINNEX products comply with international explosion-proof certification standards such as ISO, CNEX, ATEX, IECEx, SAA, EAC, ensuring safe use in different countries and regions., and BV or DNV (for offshore applications) . Depending on the product type and zone classification, we offer various protection concepts including Ex d, Ex e, Ex ib, and Ex nA, with ingress protection up to IP66/IP67, ensuring safe and compliant operation in hazardous environments worldwide.

A:

Absolutely. Explosion-proof Custom Engineering is our sixth core business. From non-standard Ex components (special material junction boxes, intrinsically safe sensors, etc.) to integrated Ex systems (skid-mounted control rooms, pressurized cabins, legacy equipment retrofitting), we provide full-process custom services covering conceptual design, 3D simulation, compliance certification, manufacturing, and delivery. Simply share your operating parameters and functional needs, and we will engineer a dedicated explosion-proof safety solution for you.

Related
Message
SUBMIT