CNWINNEX BXPK Series
Pressurized Explosion-Proof Maintenance Habitat

Pressurized Explosion-Proof Maintenance Habitat

ATEX Full-Unit Certification · Modular Quick Assembly · Safe Hot-Work Enclosure for Hazardous Areas
MESSAGE
PRODUCT DESCRIPTION

Product Overview

The CNWINNEX BXPK-Series pressurized explosion-proof maintenance habitat is a modular positive-pressure work enclosure developed for oil and gas, petrochemical, refining, LNG terminal and offshore projects. It is suitable for Zone 1 and Zone 2 gas hazardous areas and Zone 21 and Zone 22 dust hazardous areas. The unit is designed and manufactured in compliance with ATEX Directive 2014/34/EU and the EN 60079 series for pressurized enclosures (Ex pxb), carrying the explosion-proof marking Ex pxb IIC T4 Gb; Ex pxb IIIC T135℃ Db, with full-unit ATEX certification available.


By continuously maintaining positive pressure inside the shelter, the habitat prevents ingress of external flammable and toxic gases and converts a high-hazard open area into a safe internal workspace, allowing welding, cutting, maintenance and instrument commissioning to be carried out directly inside the process area without plant shutdown or temporary fire-protection scaffolding. The shelter uses a quick-assembly aluminium frame with flame-retardant anti-static fabric and an internal personnel airlock; pressurization control, gas monitoring, explosion-proof distribution and lighting are supplied as modular packages, with mainly on-site assembly and wiring to shorten the time to service.


Core Product Advantages

● Closed-Loop Pressurization with Loss-of-Pressure Interlock 

An integrated explosion-proof pressurization air-supply system and a flameproof pressurization control cabinet execute, under PLC control, the complete sequence of pre-purge, pressure build-up and operational run. A differential-pressure detection unit continuously feeds cabin pressure to the control system. When pressure falls below the safe threshold, audible and visual alarms are triggered and non-intrinsically-safe electrical loads inside the cabin are disconnected according to the interlock logic, providing fail-safe protection.

● Dual Monitoring of Combustible and Toxic Gases 

Multiple explosion-proof combustible gas detectors, a toxic gas detector and an ambient temperature detector are provided, all with local display and analogue remote output. Exceedance of gas concentration triggers alarms and participates in the interlock, keeping ignition risk outside the cabin.

● Modular Quick-Assembly Structure in Three Sizes with Cluster Deployment 

Industrial heavy-duty aluminium profiles allow quick assembly and dismantling, including foot pads, diagonal braces, connectors and lifting points. The enclosure is glass-silicone rubber flame-retardant fabric, Class B1 flame-retardant and anti-static without spark generation, fitted with observation windows and an emergency escape door. The three standard sizes can be deployed individually or networked in a three-tier arrangement of main work, utility and process workstations.

● Integrated Explosion-Proof Electrical Package Reducing Secondary Modification 

Functional packages include explosion-proof lighting, explosion-proof maintenance sockets, increased-safety junction boxes and door interlocking. An isolation transformer and main and distribution power schemes can be provided per project to match site supply voltage and provide dual-source transfer capability, so users can connect directly without additional explosion-proof modification.

● Door Interlock, Earthing and Wiring Compliance 

An explosion-proof door interlock switch on the inner door feeds door status to the pressurization control system for interlocking. Earthing terminals are provided throughout, and internal and external electrical interconnections use marine flame-retardant flexible copper cables, meeting corrosion protection and earthing requirements of offshore, tidal-flat and coastal petrochemical projects.

● Full-Unit Certification and Project-Oriented Technical Service 

All three models can be submitted for full-unit ATEX certification, with technical documents, drawings and test data supplied to support overseas EPC project tendering and third-party audits. On-site installation guidance, power-on commissioning and operator handover training are available.


Standard Sizes

Table 1  Standard sizes of the CNWINNEX BXPK-Series pressurized explosion-proof maintenance habitat

Model

Overall Dimension (L×W×H)

Positioning and Application

BXPK-4000×3000×2500

4000×3000×2500 mm

Main habitat: overhaul of large equipment, multi-person collaborative hot work

BXPK-3000×3000×2500

3000×3000×2500 mm

Utility habitat: central distribution, tool storage and transfer workstation

BXPK-2000×2000×2500

2000×2000×2500 mm

Process habitat: minor maintenance and instrument calibration at distributed points


System Composition

● The habitat is delivered as functional modules, each functionally tested and integrated before shipment. On site the work consists mainly of frame assembly, enclosure installation, and pneumatic and electrical connection, shortening the construction period.

● Structure and enclosure module: quick-assembly aluminium frame, flame-retardant anti-static fabric, airtight sealing components, observation windows, emergency escape door and internal personnel airlock, forming a sealed workspace capable of maintaining positive pressure.

● Pressurization and safety interlock module: explosion-proof air-supply unit, flameproof pressurization control cabinet, differential-pressure detection, inlet and exhaust control, together with loss-of-pressure alarm and load-shedding logic, forming a closed loop from pressurization to protection.

● Gas and environmental monitoring module: combustible gas, toxic gas and temperature detection with local display and remote transmission to the control system or site monitoring platform, with measured values participating in interlock decisions.

● Explosion-proof electrical and distribution module: explosion-proof lighting, explosion-proof maintenance sockets, increased-safety junction boxes and door interlocking, with isolation transformer and main and distribution power schemes available per project.

● Identification and cabling module: equipment nameplates, cable labels and marine flame-retardant cables, meeting site identification, corrosion protection and earthing requirements.

● Specific component selection, quantities and technical parameters are defined by the project technical agreement. Detailed configuration lists, equipment drawings and certification documents are available per project upon execution of a confidentiality agreement.


Typical Applications

● Onshore oil and gas stations and gathering stations: a main habitat inside the process area enables on-site maintenance and welding of valves, flanges, piping and pumps without full plant shutdown.

● Refining and chemical process areas: online maintenance and commissioning of instruments and electrical equipment attached to columns, heat exchangers and reactors.

● LNG terminals and storage areas: maintenance of cold boxes, pump wells and vaporiser ancillary equipment within Zone 1 and Zone 2 areas.

● Offshore platforms and tidal-flat terminals: marine flame-retardant cabling, earthing and corrosion protection configurations meet maintenance requirements in high salt-spray environments.

● Overseas EPC projects: full-unit ATEX certification and complete documentation support project tendering, with three sizes arranged as main, utility and process workstations.


Contact Us

For full-unit certification schemes, technical agreement texts, drawings and customized project support, please contact the CNWINNEX engineering team. Website: www.cnwinnex.com; 

Email: info@cnwinnex.com


FAQ
A:

CNWINNEX explosion-proof systems are widely deployed in oil & gas, petrochemicals, pharmaceuticals, ports & terminals, mining, power generation, offshore platforms, and other areas where flammable gases or dusts are present. Typical applications include control room climate control, hazardous area logistics and access management, video surveillance & security, pressurized analyzer shelters, robotic inspection, as well as custom explosion-proof enclosures and system integration.

A:

An explosion-proof air conditioner is a specialized HVAC unit designed for hazardous environments where flammable gases, vapors, or combustible dusts are present (e.g., petrochemical plants, gas stations, paint booths, pharmaceutical labs).

The most critical difference from a standard air conditioner lies in “active ignition prevention.” Standard units generate tiny sparks during normal operation – such as when relays open/close, compressors start/stop, or circuits make/break. While safe in normal air, these sparks can be deadly in an explosive atmosphere.

A:

CNWINNEX’s explosion-proof design is based on the T4 temperature class. For high-temperature regions such as the Middle East or areas with extreme summer heat, we offer custom units rated for ambient temperatures up to 60°C (140°F) , ensuring reliable operation without overload in harsh tropical climates. For cold regions, we offer custom units rated for ambient temperatures as low as -50°C (-58°F) , guaranteeing safe operation in extreme arctic conditions.

A:

The explosion-proof rating of CNWINNEX air conditioners is:
Ex 2 G D Ex db ib mb IIB T4 Gb / Ex 2 G D Ex db ib mb IIC T4 Gb / Ex ib mb tb IIIC T130°C Db
●For Gas (G): Ex db ib mb IIC T4 Gb
Suitable for IIC gas groups (including hydrogen, acetylene, etc.), using flameproof (db), intrinsic safety (ib), and encapsulated (mb) combined protection. Temperature class T4 (max surface temperature ≤135°C), Equipment Protection Level Gb.
●For Dust (D): Ex ib mb tb IIIC T130°C Db
Suitable for IIIC conductive dusts, using intrinsic safety (ib), encapsulation (mb), and dust-tight (tb) protection. Maximum surface temperature 130°C, Equipment Protection Level Db.

A:

CNWINNEX products comply with international explosion-proof certification standards such as ISO, CNEX, ATEX, IECEx, SAA, EAC, ensuring safe use in different countries and regions., and BV or DNV (for offshore applications) . Depending on the product type and zone classification, we offer various protection concepts including Ex d, Ex e, Ex ib, and Ex nA, with ingress protection up to IP66/IP67, ensuring safe and compliant operation in hazardous environments worldwide.

A:

Absolutely. Explosion-proof Custom Engineering is our sixth core business. From non-standard Ex components (special material junction boxes, intrinsically safe sensors, etc.) to integrated Ex systems (skid-mounted control rooms, pressurized cabins, legacy equipment retrofitting), we provide full-process custom services covering conceptual design, 3D simulation, compliance certification, manufacturing, and delivery. Simply share your operating parameters and functional needs, and we will engineer a dedicated explosion-proof safety solution for you.

Related
Message